Overhead Conductors & Aerial Bundled Cables
From the substation to the last house. CASK Cables supplies the bare conductors and aerial bundled cables that carry power across transmission, distribution and low-voltage networks, made to European and international standards and tested lot by lot.
The conductor decides how a line performs
A power line has to carry its current safely for decades while it hangs in the wind, the ice, the salt air or the desert heat. The right conductor keeps losses low, sag under control and maintenance to a minimum. We help utilities, EPC contractors and distribution companies choose it for each line, and supply it in drum lengths planned around the line sections so there are as few joints as possible.
CASK Cables is the cable division of CASK Electric, based in Dilovası, Kocaeli. Together with CASK Steel poles and CASK Power Systems transformers, we can supply the main materials of a line from one partner.
Four conductor families
ACSR
Aluminium wires around a galvanised steel core: the steel carries the load, the aluminium carries the current. The standard choice for high and medium voltage lines with long spans and heavy wind or ice.
AAC
All-aluminium conductor with the best conductivity for its weight and excellent corrosion resistance, for substations, busbars, short spans and coastal lines.
AAAC
Aluminium alloy conductor, about twice as strong as AAC with no steel core to rust: lower sag, fewer poles, ideal for coastal, desert and industrial areas.
Aerial bundled cables (ABC)
Insulated cores twisted around an insulated messenger for low-voltage networks along streets: no bare wires, fewer faults from trees and wind, and less electricity theft.
Sizes, technical data and item numbers for every conductor are in the catalogue: English (PDF) · العربية (PDF)
Why you can trust our conductors
International standards
Made to EN 50182, DIN and IEC 61089, with British and American standards available on request, so they fit utility specifications in many countries.
Tested lot by lot
Tensile, resistance and dimension tests on every lot, with test reports delivered for the project file.
Quality materials
High-purity EC-grade aluminium, galvanised high-strength steel and heat-treated aluminium alloy, with greased cores for coastal and desert sites on request.
Planned for your line
Drum lengths matched to your line sections, labelled drums, steel drums and export packing for long-distance transport.
Engineering advice
Our engineers help you choose between ACSR, AAC, AAAC and ABC for each line, based on span, load, corrosion and current.
One partner for the line
Conductors, steel poles, clamps and fittings, and pole-mounted transformers from the CASK Electric divisions.
Where our conductors are used
Key technical data
Main sizes and ratings from our 2026 catalogue. Item numbers, full data and drawings are in the catalogue below.
Four conductor families
| Series | Type | Sizes | Strength | Typical use |
|---|---|---|---|---|
| CSC-OH001 | ACSR: aluminium on a galvanised steel core | 16/2.5 – 300/50 mm² | Highest | HV and MV lines, long spans, heavy ice |
| CSC-OH002 | AAC: all-aluminium | 16 – 400 mm² | Lowest, best conductivity | Substations, busbars, short MV spans, coastal lines |
| CSC-OH003 | AAAC: aluminium alloy AlMgSi | 16 – 400 mm² | About twice AAC | MV lines, coastal, desert and industrial areas |
| CSC-OH004 | ABC: aerial bundled cable, Al/XLPE 0.6/1 kV | 2 × 16 – 3 × 150 + 95 mm² | Self-supporting | LV networks along streets, service drops |
ACSR conductors (CSC-OH001)
Concentric layers of hard-drawn aluminium wires around a galvanised steel core: the steel carries the mechanical load, the aluminium carries the current. The standard choice for long spans. Greased core for coastal and desert sites, and BS 215 / ASTM B232 code names, on request.
| Al/St mm² | Overall Ø | Mass | Rated tensile strength | DC R at 20 °C | Current* |
|---|---|---|---|---|---|
| 50/8 | 9.6 mm | 195 kg/km | 16.81 kN | 0.5946 Ω/km | 170 A |
| 70/12 | 11.7 mm | 284 kg/km | 26.29 kN | 0.4130 Ω/km | 290 A |
| 95/15 | 13.6 mm | 383 kg/km | 34.93 kN | 0.3058 Ω/km | 350 A |
| 120/20 | 15.5 mm | 494 kg/km | 44.50 kN | 0.2374 Ω/km | 410 A |
| 150/25 | 17.1 mm | 604 kg/km | 54.10 kN | 0.1939 Ω/km | 470 A |
| 240/40 | 21.9 mm | 985 kg/km | 86.40 kN | 0.1188 Ω/km | 645 A |
| 300/50 | 24.5 mm | 1,232 kg/km | 105.90 kN | 0.0949 Ω/km | 740 A |
* Continuous current at 35 °C ambient, 0.6 m/s wind, sun, 80 °C conductor temperature (DIN 48204 conditions). Selected sizes: the catalogue lists all 11 ACSR sizes and every AAC, AAAC and ABC size with its item number.
Frequently asked questions
ACSR, AAC or AAAC: which should I choose?
ACSR for long spans and heavy wind or ice loads; AAC for short spans, substations and busbars where conductivity matters most; AAAC for medium and long spans in coastal, desert or industrial areas where a steel core would corrode. Our engineers will confirm the choice for your line.
Do you supply aerial bundled cables for low-voltage networks?
Yes, self-supporting aerial bundled cables for street networks and service connections, with optional street-lighting cores. Clamps and fittings are available from CASK Steel.
Do the conductors come with test reports?
Yes. Every lot is tested and the test reports are delivered with the order.
Related products
Request a quotation for overhead conductors
Tell us what you need and our engineers will reply with a technical offer. Fields marked * are required.
Drawings or a full BOQ? Email them to [email protected] with your name and project.
Building or upgrading a line?
Send us the conductor type, sizes and line lengths. We reply with datasheets, a drum plan and prices.